LBZ Series oil machine for reducing dielectricloss
Application
This device is designed to purify deteriorated transformer insulating oil by physical means. The equipment uses a special adsorbent to purify and regenerate the deteriorated transformer oil and switch oil. It has the advantages of fast oil cleaning speed and oil quality protection. It can efficiently remove the acid components, suspended substances, precipitated substances and polar substances in oil. The treated oil does not damage the basic performance and oxidation resistance of the oil, and can restore the dielectric loss index of the transformer oil to the standard close to the new oil, while improving the insulation and safety performance of the oil. At the same time through adsorption filtration can improve the color of the oil, the device can be used alone, can also be used with vacuum oil filter.
Advantages
● Adopting physical and chemical methods which can keep the basic performance and oxidation resistance property of oil after treatment.
● Can improve the oil color obviously.
● Lower dielectric loss to meet the standard of new transformer oil.
● Easy operation and convenient to move.
Technical Specification
Item | Name | Unit | LBZ-I-50 | LBZ-I-100 | LBZ-I-150 | LBZ-I-200 | LBZ-II-100 | LBZ-II-200 |
Technical Parameter | Flow Rate | L/min | 50 | 100 | 150 | 200 | 100 | 100 |
Total Power | KW | 1.1 | 1.5 | 2.2 | 2.2 | 1.5 | 2.2 | |
Working Pressure | Mpa | ≤0.5Mpa | ||||||
Working Noise | dB(A) | ≤80dB | ||||||
Overall Dimensions | cm | 210×135×180 | 260×165×180 | 310×220×180 | 360×220×180 | 110×100×150 | 130×105×155 | |
Oil Quality After Treatment | Filtration Precision | μ | ≤1μm | |||||
Power Supply | V | 380V/50Hz,3-phase 4-wire (Can be customized.) | ||||||
Dielectric Loss Value | 90℃ | ≤0.02(GB5654) |
■Above size and weight are for reference only, the specific data shall be subject to its physical object.Oil treatment indicators vary with different configurations.
LBZ Series oil machine for reducing dielectricloss
Application
This device is designed to purify deteriorated transformer insulating oil by physical means. The equipment uses a special adsorbent to purify and regenerate the deteriorated transformer oil and switch oil. It has the advantages of fast oil cleaning speed and oil quality protection. It can efficiently remove the acid components, suspended substances, precipitated substances and polar substances in oil. The treated oil does not damage the basic performance and oxidation resistance of the oil, and can restore the dielectric loss index of the transformer oil to the standard close to the new oil, while improving the insulation and safety performance of the oil. At the same time through adsorption filtration can improve the color of the oil, the device can be used alone, can also be used with vacuum oil filter.
Advantages
● Adopting physical and chemical methods which can keep the basic performance and oxidation resistance property of oil after treatment.
● Can improve the oil color obviously.
● Lower dielectric loss to meet the standard of new transformer oil.
● Easy operation and convenient to move.
Technical Specification
Item | Name | Unit | LBZ-I-50 | LBZ-I-100 | LBZ-I-150 | LBZ-I-200 | LBZ-II-100 | LBZ-II-200 |
Technical Parameter | Flow Rate | L/min | 50 | 100 | 150 | 200 | 100 | 100 |
Total Power | KW | 1.1 | 1.5 | 2.2 | 2.2 | 1.5 | 2.2 | |
Working Pressure | Mpa | ≤0.5Mpa | ||||||
Working Noise | dB(A) | ≤80dB | ||||||
Overall Dimensions | cm | 210×135×180 | 260×165×180 | 310×220×180 | 360×220×180 | 110×100×150 | 130×105×155 | |
Oil Quality After Treatment | Filtration Precision | μ | ≤1μm | |||||
Power Supply | V | 380V/50Hz,3-phase 4-wire (Can be customized.) | ||||||
Dielectric Loss Value | 90℃ | ≤0.02(GB5654) |
■Above size and weight are for reference only, the specific data shall be subject to its physical object.Oil treatment indicators vary with different configurations.
What factors are responsible for dielectric loss?
One is conduction Loss wherein dissipation of energy is caused when the charge flows through the material.
The other is Dielectric Loss wherein the dissipation of energy is caused through the movement of charges in an alternating magnetic field because polarisation switches its direction.
What is the dielectric loss in an A.C field?
What is dielectric loss? Dielectric loss refers to part of the energy being dissipated within a dielectric in the form of heat when an alternating electric field is applied. Dielectric loss depends on the dielectric's properties, with its magnitude determined by the dielectric loss tangent and permittivity values.
What factors are responsible for dielectric loss?
One is conduction Loss wherein dissipation of energy is caused when the charge flows through the material.
The other is Dielectric Loss wherein the dissipation of energy is caused through the movement of charges in an alternating magnetic field because polarisation switches its direction.
What is the dielectric loss in an A.C field?
What is dielectric loss? Dielectric loss refers to part of the energy being dissipated within a dielectric in the form of heat when an alternating electric field is applied. Dielectric loss depends on the dielectric's properties, with its magnitude determined by the dielectric loss tangent and permittivity values.
LBZ Series Degraded Transformer Oil Regeneration Device13、LBZ.pdf
LBZ Series Degraded Transformer Oil Regeneration Device13、LBZ.pdf
Home / Products / About Us / Application Area / Services / News / Contact Us